Specialty Manufacturing, Inc.
Company ProfileSilicon TubingSilicon SheetingCustom ProductsContact/OrderFDA RegistrationsHome

Page Index


 

Silicone Tubing

Tubing For Your Health-Care
Sheeting Types Available
Standard Tubing Sizes
How to Clean
Sterilization
Shelf Life
Home Page


Tubing For Your
Health-Care

Application

Specialty Manufacturing is registered with the FDA as a finished medical device manufacturer. We provide silicone tubing exclusively for health-care applications.

Sheeting Types
Available
(Non-Standard
Thickness Available)



1. Durometers: 35, 50, 65, 80, Blends, Custom

2. Clear, Radiopaque, Colored

3. Sold by the 50-foot coil
  • Also available: rod and oval
  • Standard inventory: 50 durometer, clear

Standard Tubing Sizes

Standard Tubing Sizes
I.D. O.D. SMI #   I.D. O.D. SMI #
0.012 0.025 76P012-210-025 0.125 0.250 76P125-210-250
0.020 0.037 76P020-210-037 0.132 0.183 76P132-210-183
0.025 0.047 76P025-210-047 0.157 0.257 76P157-210-257
0.030 0.065 76P030-210-065 0.188 0.313 76P188-210-313
0.040 0.085 76P040-210-085 0.188 0.375 76P188-210-375
0.058 0.077 76P058-210-077 0.250 0.375 76P250-210-375
0.062 0.095 76P062-210-095 0.250 0.438 76P250-210-438
0.062 0.125 76P062-210-125 0.250 0.500 76P250-210-500
0.078 0.125 76P078-210-125 0.313 0.500 76P313-210-500
0.104 0.192 76P104-210-192 0.375 0.500 76P375-210-500
0.118 0.181 76P118-210-181

How To Clean
Tubing

Wash in a hot water and soap solution. Use a non-oily cleaner or mild soap. Do not use synthetic detergents or oil-based soaps. They can be absorbed, only to leach out into blood or other fluids later. Rinse in hot water. Follow with another rinse in distilled water
 

Sterilization

STEAM

Place on non-linting material or in a clean tray. If the tubing is to be sterilized by autoclaving, sterilize while the lumen is still wet.
Autoclave by one of the following:
  • High-speed instrument (flash) sterilizer. 10 minutes at 132 degrees Celsius (270 degrees fahrenheit) and 30 psi.
  • Standard gravity sterilizer. 30 minutes at 121 degrees celsius (250 degrees fahrenheit) and 15 psi.

RADIATION

  • Exposure at 2.5 megarads produces minimal physical property changes even at 200% elongation.

ETHYLENE OXIDE

  • Ethylene oxide will not deteriorate tubing. This method is not recommended, however, unless you know how long it takes to complete outgassing of residual ETO and other byproducts for the system you use.


Shelf Life

60 months from shipment date when stored at room temperature.
 

Contact

Specialty Manufacturing, Inc.
2210 Midland Road
Saginaw, MI 48603-3440


                  Phone: (989) 790-9011
                      Fax: (989) 790-9106

Technical Support: (800) 269-6204